Main performance indexes
1. Rated input power: dc28v
2. Input power range: dc18v ~ 36V
3. Rated output voltage: 36V AC
4. Output voltage stability: ≤± 1% at rated output (test under rated input and resistive load conditions)
5. Rated output frequency: 400Hz ± 0.5%
6. Rated output power: 50VA
7. Total harmonic content: ≤ 2%
8. Load adjustment rate: ≤± 1%
9. Voltage regulation rate: ≤± 1% (test under 80% load)
10. Output over-current protection: cut-off protection (output current is greater than 1.7A, output is closed after 10 s delay, load is connected again after 2 s, power supply automatically recovers after over-current disappears; output current is greater than 2 times of power supply
Turn off the power supply immediately for protection.
11. Input overvoltage protection: if the input voltage is greater than 40V ~ 48V, turn off the power supply immediately for protection.
12. Overheat protection: when the shell temperature exceeds 85 ℃, turn off the power supply for protection.
1. Rated input power: dc28v
2. Input power range: dc18v ~ 36V
3. Rated output voltage: 36V AC
4. Output voltage stability: ≤± 1% at rated output (test under rated input and resistive load conditions)
5. Rated output frequency: 400Hz ± 0.5%
6. Rated output power: 50VA
7. Total harmonic content: ≤ 2%
8. Load adjustment rate: ≤± 1%
9. Voltage regulation rate: ≤± 1% (test under 80% load)
10. Output over-current protection: cut-off protection (output current is greater than 1.7A, output is closed after 10 s delay, load is connected again after 2 s, power supply automatically recovers after over-current disappears; output current is greater than 2 times of power supply
Turn off the power supply immediately for protection.
11. Input overvoltage protection: if the input voltage is greater than 40V ~ 48V, turn off the power supply immediately for protection.
12. Overheat protection: when the shell temperature exceeds 85 ℃, turn off the power supply for protection.